CL-2000i

Chemiluminescence Immunoassay System

Mindray Solution for Immunoassay Tests

1

0

High Throughput

Up to 240 tests/hour

4

0

Flexible Scalability

Flexible connection with BS-800M

and BS-2000M series as well as

lab automation in the future*

*In development

Easy Operation

Intuitive interface for software

Large Capacity

Real-time indication of cuvettes, waste

300 samples in one batch

Support continuous loading

0

3

and wash buffer status

Step-by-step maintenance guide

36 onboard capacity for reagent cartridges

2

0

1134 cuvettes loaded in one batch

Thyroid

FT3

FT4

T3

T4

TSH

Anti-TG*

Anti-TPO*

Thyroglobulin (TG)*

Infectious Disease

HBsAg**

Anti-HBs**

HBeAg**

Anti-HBe**

Anti-HBc**

HIV**

Anti-HCV*

Anti-TPPA (syphilis)*

Fertility

Total β-HCG

FSH

LH

PRL

E2

E3

TESTO

PROG

Cardiac Marker*

Myoglobin

Troponin I

BNP

CK-MB(mass)

Diabetes*

Insulin

C-peptide

Test Menu

Tumor Marker

CEA

AFP

CA125

CA15-3

CA19-9

FPSA

TPSA

FERR

NSE*

CYFRA 21-1*

CA72-4*

Bone Marker*

Hormone*

PTH

ACTH

Calcitonin

DHEA-S

Vitamin D Total

Cortisol

Anemia*

Folic Acid

Vitamin B12

*In development

**CE ready in 2015

CL-2000i

Chemiluminescence Immunoassay System

Manipulator 2

Moving cuvettes for mixing, magnetic

separation and incubation

Reaction Area

100 positions for incubation

50 positions for reaction and reading

Direct solid heating

Reagent Probe

20μl-135μl, with increment of 1μl

Bubble detection, liquid level detection

Collision protection and auto recovery

Enhanced exterior and interior washing

Reagent Carousel

36 onboard capacity for reagent cartridges

2°C~8°C constant cooling compartment

Continuous reagent loading

Normal Lane

Return Lane

Passing Lane

Higher priority for STAT, calibrator, control and rerun racks

For routine sample racks transferred to other analytical unit(s)

Sample Probe

10μl-200μl, with increment of 1μl

Clot detection, liquid level detection and tracking

Collision protection and auto recovery

Enhanced exterior and interior washing

Cuvettes Area

9 boxes of cuvettes can be loaded in one batch

126 cuvettes per box

Automatic unloading for empty boxes

System Layout

Mixing Unit

High speed vortex mixing for reaction solution

Magnetic Separation Unit

4-step washing

Sample Delivery Module (SDM)

Up to 300 samples to be loaded

Continuous sample loading and offloading

STAT and RUN buttons

Flexible STAT rack loading

One touch to initiate analysis

Substrate Bottles

2 bottles for equilibrium

2 bottles ready for aspirating

Bottom piercing to eliminate contamination

Manipulator 1

Moving cuvettes for dispensing

Intelligent cuvette detection

Reliable Results

Enhanced Reaction System

Non-touch vortex mixing for reaction solution without any contamination

Precisely controlled temperature for magnetic separation, incubation &

reaction by maintenance free direct-solid heating technology

Reliable clinical performance with enhanced PMT chemiluminescent

detection system

Ef

ficient Washing System

Interior & exterior probe washing with high pressure pre-heated water

Programmed enhanced washing with detergent for reagent and sample probes

4-step washing for magnetic separation unit with high efficiency

Stable Reagent Cartridges Utility

2°C~8°C constant cooling compartment for reagents cartridges

Membrane sealed liquid reagent ready-to-use

Intelligent magnetic particles mixing by reagent carousel rotation

Intelligent Indication for Daily Operation

Real-time indication of cuvettes, waste and wash buffer status

Real-time monitoring for substrates consumption

Easy operation for replacing cuvettes, wash buffer and placing new

substrates

Advanced Software

User-friendly Interface

Unified platform of BS-2000M series, BS-800M series, BS-480 and future system

Real-time status monitoring for analytical unit, SDM and carousels

Intelligent distribution for STAT samples

Real-time QC Status Monitoring

Westgard Rules and Two-Control Evaluation check

Levey-Jennings chart and Twin-Plot chart for review

Real-time alarm and locating when QC result(s) is out of range

Auto QC setup capability

Traceable Test Results

Reagent, calibrator and control information can be recalled

from archive history

Intuitive software design, easy to trace results

Reflex and Re-run Function

Pre-defined reflex and Re-run assays will be performed

automatically when preset criteria is met

Test Summary Function

Test summary during certain period, including calibration, QC, Sample, valid

tests and rerun tests

Facilitate to computation of total test costs within a defined period

The summary can be archived into excel files or printed to review and backup

Step-by-step Maintenance Guide

Scheduled maintenance and maintenance guide for analytical unit

Ensure performance reliability and reduce unnecessary service calls

Error report transferrable to service engineers for immediate

troubleshooting which can minimize instrument downtime

CL-2000i

Chemiluminescence Immunoassay System

Technical Specifications

General Information

Magnetic Separation Unit

Throughput Up to 240 tests/hour

Separation Assembly

Measurement Principle

4-step magnetic separation with unique

Micron superparamagnetic particles platform

separation buffer

with alkaline phosphatase (ALP) labled

Temperature Accuracy: 37±0.3

°C

, fluctuation: ±0.1

°C

reagents and AMPPD substrate

Wash Buffer Ready for use

Real-time monitoring for status

Sample Assembly

Sample Feeder Rack system with Sample Delivery Module

Measurement and Reaction System

Up to 300 onboard samples with 30 racks.

Detection Mode Photon counter

Sample Probe Steel probe, liquid level detection, clot

Reference Source LED

detection, horizontal and vertical collision

Detector PMT

protection

Reaction Disk 150 positions

Sample Volume 10µl~200µl, with increment of 1µl

Cuvette Disposable

Sample Dilution Automatic dilution with 1:2 ~ 1:40

Cuvette Loading Cassette assembly, 1134 onboard cuvettes

Waste Cuvette Recycling

Reagent Assembly

2 waste boxes, overflow detection for cuvette

Reagent Disk 36 reagent positions, continuous loading,

recycling assembly

real-time mixing for magnetic particles

Temperature Accuracy: 37±0.3

°C

, Fluctuation: ±0.1

°C

Cooling System

2°C~8°C

Mixing Unit Non-touch vortex mixing

Reagent Barcode Automatic scanning

Reaction Volume Sample and reagent reaction

Reagent Probe Steel probe, liquid level detection, bubble

volume: maximal 350 ul

detection, horizontal and vertical collision

Auto-dilution sample and reagent mixing

protection

volume: maximal 400 ul

Reagent Volume 20µl~135µl, with increment of 1µl

Working Conditions

Substrate System

Power Supply 110V/115V~, 60Hz; 220V-240V~, 50Hz;

Substrate Bottle 500 tests per bottle, bottom piercing

20V/230V~, 60Hz

Substrate Loading Capable of continuous loading during testing

Input Power 3200VA

2 bottles ready for aspiriting,

Operating Temperature 15

°C

~30

°C

and 2 bottles for equilibrium

Relative Humidity 35%RH~80%RH, without condesation

Substrate Heating Constant heating

Dimension(mm) Main Unit: 1450mm*1020mm*1200mm (W*D*H)

Aspiration Volume 200µl

SDM: 710mm*1020mm*1200mm (W*D*H)

Total: 2150mm*1020mm*1200mm (W*D*H))

Weight: 550kg

Altitude -400m~2000m

(optional external compressor for 2000m~4000m)

Mindray Building, Keji 12th Road South,

High-tech Industrial Park, Nanshan, Shenzhen 518057, P.R. China

2013 Shenzhen Mindray Bio-Medical Electronics Co., Ltd. All rights reserved.

Specifications subject to changes without prior notice.

Tel: +86 755 8188 8998 Fax: +86 755 26582680

P/N: ENG-CL2000i-21285x8-20130902