CL-2000i
Chemiluminescence Immunoassay System
Mindray Solution for Immunoassay Tests
1
0
High Throughput
Up to 240 tests/hour
4
0
Flexible Scalability
Flexible connection with BS-800M
and BS-2000M series as well as
lab automation in the future*
*In development
Easy Operation
Intuitive interface for software
Large Capacity
Real-time indication of cuvettes, waste
300 samples in one batch
Support continuous loading
0
3
and wash buffer status
Step-by-step maintenance guide
36 onboard capacity for reagent cartridges
2
0
1134 cuvettes loaded in one batch
Thyroid
FT3
FT4
T3
T4
TSH
Anti-TG*
Anti-TPO*
Thyroglobulin (TG)*
Infectious Disease
HBsAg**
Anti-HBs**
HBeAg**
Anti-HBe**
Anti-HBc**
HIV**
Anti-HCV*
Anti-TPPA (syphilis)*
Fertility
Total β-HCG
FSH
LH
PRL
E2
E3
TESTO
PROG
Cardiac Marker*
Myoglobin
Troponin I
BNP
CK-MB(mass)
Diabetes*
Insulin
C-peptide
Test Menu
Tumor Marker
CEA
AFP
CA125
CA15-3
CA19-9
FPSA
TPSA
FERR
NSE*
CYFRA 21-1*
CA72-4*
Bone Marker*
Hormone*
PTH
ACTH
Calcitonin
DHEA-S
Vitamin D Total
Cortisol
Anemia*
Folic Acid
Vitamin B12
*In development
**CE ready in 2015
CL-2000i
Chemiluminescence Immunoassay System
Manipulator 2
Moving cuvettes for mixing, magnetic
separation and incubation
Reaction Area
100 positions for incubation
50 positions for reaction and reading
Direct solid heating
Reagent Probe
20μl-135μl, with increment of 1μl
Bubble detection, liquid level detection
Collision protection and auto recovery
Enhanced exterior and interior washing
Reagent Carousel
36 onboard capacity for reagent cartridges
2°C~8°C constant cooling compartment
Continuous reagent loading
Normal Lane
Return Lane
Passing Lane
Higher priority for STAT, calibrator, control and rerun racks
For routine sample racks transferred to other analytical unit(s)
Sample Probe
10μl-200μl, with increment of 1μl
Clot detection, liquid level detection and tracking
Collision protection and auto recovery
Enhanced exterior and interior washing
Cuvettes Area
9 boxes of cuvettes can be loaded in one batch
126 cuvettes per box
Automatic unloading for empty boxes
System Layout
Mixing Unit
High speed vortex mixing for reaction solution
Magnetic Separation Unit
4-step washing
Sample Delivery Module (SDM)
Up to 300 samples to be loaded
Continuous sample loading and offloading
STAT and RUN buttons
Flexible STAT rack loading
One touch to initiate analysis
Substrate Bottles
2 bottles for equilibrium
2 bottles ready for aspirating
Bottom piercing to eliminate contamination
Manipulator 1
Moving cuvettes for dispensing
Intelligent cuvette detection
Reliable Results
Enhanced Reaction System
Non-touch vortex mixing for reaction solution without any contamination
Precisely controlled temperature for magnetic separation, incubation &
reaction by maintenance free direct-solid heating technology
Reliable clinical performance with enhanced PMT chemiluminescent
detection system
Ef
ficient Washing System
Interior & exterior probe washing with high pressure pre-heated water
Programmed enhanced washing with detergent for reagent and sample probes
4-step washing for magnetic separation unit with high efficiency
Stable Reagent Cartridges Utility
2°C~8°C constant cooling compartment for reagents cartridges
Membrane sealed liquid reagent ready-to-use
Intelligent magnetic particles mixing by reagent carousel rotation
Intelligent Indication for Daily Operation
Real-time indication of cuvettes, waste and wash buffer status
Real-time monitoring for substrates consumption
Easy operation for replacing cuvettes, wash buffer and placing new
substrates
Advanced Software
User-friendly Interface
Unified platform of BS-2000M series, BS-800M series, BS-480 and future system
Real-time status monitoring for analytical unit, SDM and carousels
Intelligent distribution for STAT samples
Real-time QC Status Monitoring
Westgard Rules and Two-Control Evaluation check
Levey-Jennings chart and Twin-Plot chart for review
Real-time alarm and locating when QC result(s) is out of range
Auto QC setup capability
Traceable Test Results
Reagent, calibrator and control information can be recalled
from archive history
Intuitive software design, easy to trace results
Reflex and Re-run Function
Pre-defined reflex and Re-run assays will be performed
automatically when preset criteria is met
Test Summary Function
Test summary during certain period, including calibration, QC, Sample, valid
tests and rerun tests
Facilitate to computation of total test costs within a defined period
The summary can be archived into excel files or printed to review and backup
Step-by-step Maintenance Guide
Scheduled maintenance and maintenance guide for analytical unit
Ensure performance reliability and reduce unnecessary service calls
Error report transferrable to service engineers for immediate
troubleshooting which can minimize instrument downtime
CL-2000i
Chemiluminescence Immunoassay System
Technical Specifications
General Information
Magnetic Separation Unit
Throughput Up to 240 tests/hour
Separation Assembly
Measurement Principle
4-step magnetic separation with unique
Micron superparamagnetic particles platform
separation buffer
with alkaline phosphatase (ALP) labled
Temperature Accuracy: 37±0.3
°C
, fluctuation: ±0.1
°C
reagents and AMPPD substrate
Wash Buffer Ready for use
Real-time monitoring for status
Sample Assembly
Sample Feeder Rack system with Sample Delivery Module
Measurement and Reaction System
Up to 300 onboard samples with 30 racks.
Detection Mode Photon counter
Sample Probe Steel probe, liquid level detection, clot
Reference Source LED
detection, horizontal and vertical collision
Detector PMT
protection
Reaction Disk 150 positions
Sample Volume 10µl~200µl, with increment of 1µl
Cuvette Disposable
Sample Dilution Automatic dilution with 1:2 ~ 1:40
Cuvette Loading Cassette assembly, 1134 onboard cuvettes
Waste Cuvette Recycling
Reagent Assembly
2 waste boxes, overflow detection for cuvette
Reagent Disk 36 reagent positions, continuous loading,
recycling assembly
real-time mixing for magnetic particles
Temperature Accuracy: 37±0.3
°C
, Fluctuation: ±0.1
°C
Cooling System
2°C~8°C
Mixing Unit Non-touch vortex mixing
Reagent Barcode Automatic scanning
Reaction Volume Sample and reagent reaction
Reagent Probe Steel probe, liquid level detection, bubble
volume: maximal 350 ul
detection, horizontal and vertical collision
Auto-dilution sample and reagent mixing
protection
volume: maximal 400 ul
Reagent Volume 20µl~135µl, with increment of 1µl
Working Conditions
Substrate System
Power Supply 110V/115V~, 60Hz; 220V-240V~, 50Hz;
Substrate Bottle 500 tests per bottle, bottom piercing
20V/230V~, 60Hz
Substrate Loading Capable of continuous loading during testing
Input Power 3200VA
2 bottles ready for aspiriting,
Operating Temperature 15
°C
~30
°C
and 2 bottles for equilibrium
Relative Humidity 35%RH~80%RH, without condesation
Substrate Heating Constant heating
Dimension(mm) Main Unit: 1450mm*1020mm*1200mm (W*D*H)
Aspiration Volume 200µl
SDM: 710mm*1020mm*1200mm (W*D*H)
Total: 2150mm*1020mm*1200mm (W*D*H))
Weight: 550kg
Altitude -400m~2000m
(optional external compressor for 2000m~4000m)
Mindray Building, Keji 12th Road South,
High-tech Industrial Park, Nanshan, Shenzhen 518057, P.R. China
2013 Shenzhen Mindray Bio-Medical Electronics Co., Ltd. All rights reserved.
Specifications subject to changes without prior notice.
Tel: +86 755 8188 8998 Fax: +86 755 26582680
P/N: ENG-CL2000i-21285x8-20130902
E-mail: intl-market@
Mindray is listed on the NYSE under the symbol”MR”