Technical Data
10 22 26 (10650)
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
THE ACOUSTI-SEAL PAIRED PANEL SYSTEM
• Used in straight-line openings that do not re-
quire multiple locations or offset storage
• No auxiliary storage track or support required
• Panels are hinged together in groups of two
and provide quick and easy setup
• Ideally suited for applications that require
exceptional durability, acoustic control, and
frequent use
Modernfold Model
Acousti-Seal 932
• Floor-supported (932FS) paired panels are
available for installations where the existing
overhead structure cannot support the
partition’s weight
• Used in classrooms, conference or meeting
rooms, and office space
Flat Panels, Paired Panel Operation
This specification along with product information and model details can be downloaded from
SPECIFICATION - SECTION
10 22 26 (10650)
OPERABLE PARTITIONS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
gs and general provisions of the Contract,
including General and Supplementary Conditions
and Division 1 Specification Sections, apply to this
Section.
1.2 SUMMARY
A. This Section includes the following:
1. Manually operated, paired panel operable partiti-
ons.
B. Related Sections include the following:
1. Division 3 Sections for concrete
tolerances required.
2. Division 5 Sections for primary structural sup-
port, including pre-punching of support members
by structural steel supplier per operable partition
supplier’s template.
3. Division 6 Sections for wood framing and sup-
ports, and all blocking at head and jambs
as required.
4. Division 9 Sections for wall and ceiling framing
at head and jambs.
1.3 QUALITY ASSURANCE
A. Installer Qualifications: An experienced installer
who is certified in writing by the operable partition
manufacturer, as qualified to install the manufactu-
rer’s partition systems for work similar
in material, design, and extent to that indicated
for this Project.
B. Acoustical Performance: Test operable partitions in
an independent acoustical laboratory in accordance
with ASTM E90 test procedure to attain no less
than the STC rating specified. Provide a complete
and unedited written test report by the testing
laboratory upon request.
C. Preparation of the opening shall conform to the
criteria set forth per ASTM E557 Standard Practice
for Architectural Application and Installation of
Operable Partitions.
1.4 SUBMITTALS
A. Product Data: Material descriptions, construction
details, finishes, installation details, and operating
instructions for each type of operable partition,
component, and accessory specified.
B. Shop Drawings: Show location and extent of opera-
ble partitions. Include plans, elevations, sections,
details, attachments to other construction, and
accessories. Indicate dimensions, weights, conditi-
ons at openings, and at storage areas, and required
installation, storage, and operating clearances.
Indicate location and installation requirements for
hardware and track, including floor tolerances
required and direction of travel. Indicate blocking
to be provided by others.
C. Setting Drawings: Show imbedded items and cut-
outs required in other work, including support beam
punching template.
1Please contact your local Modernfold distributor for further assistance, or visit our website at .
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
D. Samples: Color samples demonstrating full range of
finishes available by architect. Verification samples
will be available in same thickness and material
indicated for the work.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Clearly mark packages and panels with numbering
systems used on Shop Drawings. Do not use perma-
nent markings on panels.
B. Protect panels during delivery, storage, and hand-
ling to comply with manufacturer’s direction and as
required to prevent damage.
1.6 WARRANTY
A. Provide written warranty by manufacturer of opera-
ble partitions agreeing to repair or replace
any components with manufacturing defects.
B. Warranty period: Two (2) years.
PART 2 – PRODUCTS
2.1 MANUFACTURERS, PRODUCTS, AND OPERA-
TION
A. Manufacturers: Subject to compliance with require-
ments, provide products by the following:
1. Modernfold, Inc.
B. Products: Subject to compliance with the require-
ments, provide the following product:
1. Acousti-Seal #932 manually operated
paired panel operable partition.
2.2 OPERATION
A. Acousti-Seal #932: Series of paired flat
panels hinged together in pairs, manually operated,
top supported with operable floor seals.
B. Final Closure (select one):
1. Horizontally expanding panel edge with remova-
ble crank
2. Hinged panel closure
3. Angle Jamb
4. Pass door closure
5. Spinner panel
2.3 PANEL CONSTRUCTION
A. Nominal 3-inch (76 mm) thick panels in manufac-
turer’s standard 48-inch (1220 mm) widths. All
panel horizontal and vertical framing members
fabricated from minimum 18-gage formed steel
with overlapped and welded corners for rigidity.
Top channel is reinforced to support suspension
system components. Frame is designed so that full
vertical edges of panels are of formed steel and
provide concealed protection of the edges of the
panel skin.
B. Panel Skin Options:
1. 1/2-inch (13 mm) tackable 100% recycled
gypsum board, class “A” rated single material
or composite layers continuously bonded to
panel frame. Acoustical ratings of panels with
this construction (select one):
a. 41 STC
b. 47 STC
c. 50 STC
2. 1/2-inch (13 mm) tackable 100% recycled
moisture resistant gypsum board, class “A”
rated single material or composite layers
continuously bonded to panel frame. Acoustical
ratings of panels with this construction (select one):
a. 41 STC
b. 47 STC
c. 50 STC
3. 1/2-inch (13 mm) NAUF medium density
fiberboard, single material or composite layers
continuously bonded to panel frame. Acoustical
ratings of panels with this construction (select one):
a. 41 STC
b. 47 STC
c. 50 STC
4. Roll-formed steel wrapping around panel edge.
Panel skins shall be lock formed and welded
directly to the frame for unitized construction.
Acoustical ratings of panels with this construc-
tion (select one):
a. 45 STC
b. 50 STC
c. 52 STC
C. Hinges for Panels, Closure Panels, Pass Doors, and
Pocket Doors shall be (select one):
1. Full leaf butt hinges, attached directly to panel
frame with welded hinge anchor plates within
panel to further support hinge mounting to
frame. Lifetime warranty on hinges. Hinges
mounted into panel edge or vertical astragal
are not acceptable.
2Please contact your local Modernfold distributor for further assistance, or visit our website at .
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
2. SOSS® Invisible laminated hinge with antifriction
segments mounted between each heat treated
link. Hinge to be attached directly to panel
frame. Welded internal hinge bracket shall sup-
port the hinge and allow for adjustment of hinge
plates. Concealed hinges mounted into panel
edge or vertical astragal are not acceptable (avai-
lable on steel skin panel only).
D. Panel Trim: No vertical trim required or allowed
on edges of panels; minimal groove appearance
at panel joints.
E. Panel Weights:
Non-Steel Skin
1. 41 STC – 6.5 lbs./square foot
2. 47 STC – 7 lbs./square foot
3. 50 STC – 8 lbs./square foot
Steel Skin
1. 45 STC – 8 lbs./square foot
2. 50 STC – 8 lbs./square foot
3. 52 STC – 11 lbs./square foot
2.4 PANEL FINISHES
A. Panel Face finish shall be (select as required):
1. Reinforced vinyl with woven backing weighing
not less than 15 ounces per lineal yard.
2. Reinforced heavy-duty vinyl with woven backing
weighing not less than 27 ounces per lineal yard.
3. Acoustical, non-woven needle punch carpet, with
fused fibers to prevent unraveling or fray of
material.
4. Wall covering and upholstery fabric with surface
treatment to resist stains.
5. Customer’s own material (subject to factory
approval).
6. Full height tackboard with vinyl or fabric covering.
a. 1/4-inch natural cork
b. 1/4-inch fiber board tackbase
7. Full height steel work surfaces (chalkboard or
dry marker board).
8. High pressure plastic laminate on MDF board.
9. Wood veneer on MDF board.
10. Uncovered for field finishing.
11. Primed for field finishing.
B. Panel Trim: Exposed panel trim of one consistent
color.
2.5 SOUND SEALS
A. Vertical Interlocking Sound Seals between panels:
Roll-formed steel astragals, with reversible tongue
and groove configuration in each panel edge for
universal panel operation. Rigid plastic astragals or
astragals in only one panel edge are not acceptable.
B. Horizontal Top Seals: Continuous contact extruded
vinyl bulb shape with pairs of non-contacting vinyl
fingers to prevent distortion without the need for
mechanically operated parts.
C. Horizontal Bottom Seals (select one):
1. Modernfold IA2 bottom seal: Automatic operable
seals providing nominal 2-inch (51 mm) opera-
ting clearance with an operating range of +1/2-
inch (13 mm) to –1-1/2-inch (38 mm) which
automatically drop as panels are positioned,
without the need for tools or cranks.
2. Modernfold IM2 bottom seal: Manually activated
bottom seals with self contained handle providing
nominal 2-inch (51 mm) operating clearance with
an operating range of +1/2-inch (13 mm) to
–1-1/2-inch(38 mm). Seal shall be operable from
panel edge or face.
3. Modernfold IC2 bottom seal: Manually activated
operable bottom seals with removable handle
providing nominal 2-inch (51 mm) operating
clearance with an operating range of +1/2-inch
(13 mm) to –1-1/2-inch (38 mm). Seal shall be
operable from panel edge or face.
2.6 SUSPENSION SYSTEM (select one)
A. #17 Suspension System
1. Suspension Tracks: Minimum 11-gage,
0.12-inch (3.04 mm) roll-formed steel track,
suitable for either direct mounting to a wood
header or supported by adjustable steel hanger
brackets, supporting the load-bearing surface of
the track, connected to structural support by
pairs of 3/8-inch (9.5 mm) diameter threaded
rods. Aluminum track is not acceptable.
a. Exposed track soffit: Steel, integral to track,
and pre-painted off-white.
2. Carriers: One all-steel trolley with steel-tired ball
bearing wheels per panel (except hinged panels).
Non-steel tires are not acceptable.
- OR -
Please contact your local Modernfold distributor for further assistance, or visit our website at .3
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
B. #30 Suspension System
1. Suspension Tracks: Track shall be structural
aluminum. Static loading of track with brackets
at 48-inch (1220 mm) centers shall show no
failure of track or brackets at 5,000 pounds
(2250 kg) point loading at mid-span. Track shall
be supported by adjustable steel hanger brackets
connected to structural support by pairs of
3/8-inch (9.5 mm) diameter threaded rods.
a. Exposed track soffit: Track soffit to be integral
to track shape and shall be powder-coated off-
white paint finish. Track must accommodate
termination of plenum sound barriers on both
sides of track for maximum sound control.
2. Carriers: One trolley per panel with 3-inch
(76.2 mm) diameter glass-reinforced nylon
all steel precision-ground ball-bearing wheels.
Steel-wheeled or reinforced polymer trolleys
on aluminum track not permitted. Trolleys shall
attach to panels with 1/2-inch (12.7 mm) diame-
ter pendent bolt mounted to welded
steel mounting plate.
- OR -
C. #14 Suspension System
1. Suspension Tracks: Minimum 7-gage, 0.18-inch
(4.57 mm) roll formed steel. Static loading of
track with brackets at 48-inch (1220 mm) cen-
ters shall show no failure of track or brackets at
5,000 pounds (2550 kg) point loading at
mid-span. Track shall be supported by adjustable
steel hanger brackets connected to structural
support pairs of 1/2-inch (13 mm) diameter
threaded rods. Brackets must support the load
bearing surface of the track.
a. Exposed track soffit: Steel, removable for
service and maintenance, attached to track
bracket without exposed fasteners, and
pre-painted off-white.
2. Carriers: One all steel trolley with steel-tired ball
bearing wheels per panel (except hinged panels).
Non-steel tires are not acceptable.
2.7 OPTIONS
A. Single Pass Doors (select one):
1. Standard hollow metal door hung in a steel frame.
ADA-compliant pass door to be equipped with
friction latch and flush pulls for panic operation.
No threshold will be permitted.
a. Pass door to be prime painted for field finishing.
door to be of one consistent color from
manufacturer’s standard offering.
2. Matching pass door same thickness and appea-
rance as panels. ADA-compliant pass door to be
trimless and equipped with friction latch and
flush pulls for panic operation. No threshold will
be permitted.
3. Hardware
a. Automatic door closures.
b. Self-Illuminated exit signs.
c. Panic hardware.
B. Work Surfaces:
1. Markerboard: White enamel on steel, bonded to
the face of the panel with horizontal trim without
exposed fasteners. Trim is not acceptable on
vertical edges to provide uninterrupted work
surface.
2. Chalkboard: Porcelain enamel on steel, bonded
to the face of the panel with horizontal trim
without exposed fasteners. Trim is not acceptable
on vertical edges to provide uninterrupted work
surface.
3. Tackboard: Minimum 1/4-inch (6.35 mm) natural
cork, covered with vinyl or fabric, with horizontal
trim without exposed fasteners. Trim is not
acceptable on vertical edges.
C. Available Accessories/Options:
1. Pocket Doors: Acousti-Seal Pocket Doors by
Modernfold, Inc., with same construction, finish,
and appearance as the adjacent panels.
2. Finished end caps.
3. Intersecting partition interface.
4. Inset window options - glazed or unglazed.
PART 3 – EXECUTION
3.1 INSTALLATION
A. General: Comply with ASTM E557, operable parti-
tion manufacturer’s written installation instructions,
Drawings and approved Shop Drawings.
B. Install operable partitions and accessories after
other finishing operations, including painting have
been completed.
C. Match operable partitions by installing panels from
marked packages in numbered sequence indicated
on Shop Drawings.
D. Broken, cracked, chipped, deformed, or unmatched
panels are not acceptable.
4Please contact your local Modernfold distributor for further assistance, or visit our website at .
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
3.2 CLEANING AND PROTECTION
A. Clean partition surfaces upon completing installa-
tion of operable partitions to remove dust, dirt,
adhesives, and other foreign materials according to
manufacturer’s written instructions.
B. Provide final protection and maintain conditions in
3.4 EXAMINATION
A. Examine flooring, structural support, and opening,
with Installer present, for compliance with require-
ments for installation tolerances and other conditi-
ons affecting performance of operable partitions.
Proceed with installation only after unsatisfactory
a manner acceptable to the manufacturer andconditions have been corrected.
Installer that insure operable partitions are without
damage or deterioration at time of Substantial
3.5 DEMONSTRATION
Completion.
A. Demonstrate proper operation and maintenance
procedures to Owner’s representative.
3.3 ADJUSTINGB. Provide Operation and Maintenance Manual to
A. Adjust operable partitions to operate smoothly,Owner’s representative.
easily, and quietly, free from binding, warp, exces-
sive deflection, distortion, nonalignment, misplace-
ment, disruption, or malfunction, throughout entire
operational range. Lubricate hardware and other
moving parts.
STC CONSTRUCTION AND TRACK SYSTEM HEIGHT LIMITATIONS
Non-Steel Skin Max Height
Welded Steel Skin Max Height
Acoust-Seal 932
41 STC47 STC50 STC45 STC50 STC52 STC
#17 Direct Mounted Track14'-2"12'-2"10'-2"10'-2"10'-2"
#17 Bracket Mounted Track18'-2"18'-2"16'-2"16'-2"16'-2"12'-2"
#14 Bracket Mounted Track18'-2"18'-2"18'-2"18'-2"18'-2"18'-2"
#30 Bracket Mounted Track18'-2"18'-2"16'-2"16'-2"12'-2"10'-2"
Please contact your local Modernfold distributor for further assistance, or visit our website at .5
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
STEEL SKIN PANEL CONSTRUCTION
Acousti-Seal 932
Panel SectionFrame Details
PANEL DETAILS ARE NOT TO SCALE
Acousti-Seal 932
Standard Panel Joint
Roll-formed skin wraps completely around the edge of
vertical 16 ga. steel channel and is locked in place,
eliminating any sharp edges and creating a unitized
panel. The outer covering is secured under the steel
astragal to prevent peeling.
ROLL-FORMED EDGES
WRAPPED AROUND,
LOCKED AND WELDED
TO VERTICAL FRAME
STEEL DUAL INTERLOCKING
VERTICAL ASTRAGAL
WITH VINYL ACOUSTICAL
GASKET
ROLL-FORMED
STEEL VERTICAL
FRAME CHANNEL
WITH NO SHARP
EDGES
MINIMUM GROOVE
AT PANEL JOINT WITH
NO VERTICAL EDGE TRIM
Model Detail from Website
NON-DISTORTING
BULB-AND-FINGER
ACOUSTICAL SWEEP
UNDERSIDE OF
TRACK/SOFFIT
FORMED STEEL SKIN
WITH NO SHARP
EDGES WELDED TO
FRAME
NOMINAL 21 GA. STEEL SKINS
WITH ACOUSTICAL BACKER
DOUBLE 16 GA.
STEEL TOP
CHANNEL WITH
HEAVY STEEL
CORNER
REINFORCEMENTS
ACOUSTICAL
INSULATION
16 GA. ROLL-FORMED
STEEL VERTICAL
FRAME CHANNEL
.75" (19 mm)
SOLID STEEL
TROLLEY MOUNT
AS-41
INSULATED BOTTOM
SEAL CAVITY WITH
DOUBLE ACOUSTICAL
SEALS
16 GA. FORMED
STEEL BOTTOM
FRAME CHANNEL
Heavy steel hinges are mounted directly to the center of
the vertical frame channel, not simply on the outside
edge of the panel. Steel plates on the back of the chan-
nel prevent buckling or bending and provide the stron-
gest hinged connection.
FINISH MATERIAL WRAPPED
AROUND PANEL EDGE AND
CAPTURED BY VERTICAL
ASTRAGAL
SELF-CONTAINDED,
SERVICEABLE
BOTTOM SEALS
DUAL-DUROMETER
FLOOR SEAL WITH
CONTOUR MATCHING
OUTER SEALS
FLOOR
ROLL-FORMED EDGES
WRAPPED AROUND, LOCKED AND
WELDED TO VERTICAL FRAME
STEEL BUTT
HINGES ATTACH
DIRECTLY TO
FRAME WITH
HEAVY STEEL
BACKER PLATES
16 GA. ROLL-FORMED
STEEL VERTICAL FRAME
CHANNEL WITH NO
SHARP EDGES
Model Detail from Website
AS-42R
6Please contact your local Modernfold distributor for further assistance, or visit our website at .
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
NON-STEEL SKIN PANEL CONSTRUCTION
Acousti-Seal 932
Panel SectionFrame Details
PANEL DETAILS ARE NOT TO SCALE
Acousti-Seal 932
Standard Panel Joint
Roll-formed vertical frame channel provides added
strength while eliminating any sharp edges. The outer
covering is secured under the steel astragal to pre-
vent peeling. The complete vertical edge of the panel
is steel for maximum durability.
BUILT-IN CONCEALED
EDGE PROTECTION
FOR PANEL SKIN
UNDERSIDE OF
TRACK/SOFFIT
FINISH MATERIAL WRAPPED
AROUND PANEL EDGE AND
CAPTURED BY VERTICAL
ASTRAGAL
FULL WIDTH
LAMINATED
PANEL SKIN WITH
CONTINUOUS
PERIMETER BOND
BULB-AND-FINGER
ACOUSTICAL SWEEP
14 GA.
REINFORCED
FORMED STEEL
TOP CHANNEL
.63" (16 mm)
SOLID STEEL
TROLLEY MOUNT
FULL PERIMETER
18 GA. STEEL
FRAME WITH
OVERLAPPED
AND WELDED
CORNERS
ACOUSTICAL
INSULATION
18 GA. ROLL-FORMED
STEEL VERTICAL FRAME
CHANNEL WITH NO
SHARP EDGES
FINE LINE PANEL
JOINT WITH NO
VERTICAL EDGE TRIM
STEEL DUAL INTERLOCKING
VERTICAL ASTRAGAL WITH
VINYL ACOUSTICAL GASKET
Model Detail from Website
NG-68
FORMED STEEL
BOTTOM FRAME
CHANNEL WITH
BOTTOM EDGE
PROTECTION
Heavy steel hinges are mounted directly to the cen-
ter of the vertical frame channel, not simply on the
outside edge of the panel. Steel plates on the back
of the channel prevent buckling or bending and
provide the strongest hinge connection.
STEEL BUTT HINGES ATTACH
DIRECTLY TO HEAVY STEEL
BACKER PLATES WELDED TO
FRAME
FINISH MATERIAL WRAPPED
AROUND PANEL EDGE AND
CAPTURED BY VERTICAL
ASTRAGAL
INSULATED BOTTOM
SEAL CAVITY
WITH DOUBLE
ACOUSTICAL SEALS
FULL WIDTH
LAMINATED
PANEL SKIN WITH
CONTINUOUS
PERIMETER BOND
SELF-CONTAINED,
SERVICEABLE
BOTTOM SEALS
DUAL-DUROMETER
FLOOR SEAL WITH
CONTOUR MATCHING
OUTER SEALS
ACOUSTICAL
INSULATION
18 GA. ROLL-FORMED
STEEL VERTICAL FRAME
CHANNEL WITH NO
SHARP EDGES
FINE LINE PANEL
JOINT WITH NO
VERTICAL EDGE TRIM
BUILT-IN CONCEALED
EDGE PROTECTION
FOR PANEL SKIN
STEEL DUAL
INTERLOCKING VERTICAL
ASTRAGAL WITH VINYL
ACOUSTICAL GASKET
FLOOR
Model Detail from Website
NG-69R
7Please contact your local Modernfold distributor for further assistance, or visit our website at .
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
SUSPENSION SYSTEM OPTIONS
#17 Track System Direct Mount
DOUBLE 2" (51 mm)
× 10" (254 mm) MIN.
HEADER REQUIRED
@ STACK AREA
CONTINUOUS AND LEVEL
HEADER NOT BY
MODERNFOLD
RECOMMENDED SOUND
BAFFLE NOT BY
MODERNFOLD
2
.
1
2
"
2
.
5
0
"
(
5
4
m
m
)
(
6
4
m
m
)
M
I
N
.
#14 × 2.50" (64 mm)
TYPE A SCREW
@6" O.C
#17 STEEL TRACK AND
ALUMINUM GUIDE RAIL
PREPAINTED OFF WHITE
STEEL, 4-WHEEL
PRECISION GROUND AND
SEALED BALLBEARING
TROLLEYS
.75"
(19 mm)
VINYL TOP SEAL
Model Detail from Website
4.25"
(108 mm)
TRACK
AS-04
#17 Track System Bracket Mount
5.75"
(146 mm)
BRACKET
4.50"
(114 mm)
GAGE
4
"
(
1
0
2
m
m
)
M
I
N
.
.38" (10 mm) DIA.
× 7" (178 mm) LONG
HANGER RODS
BY MODERNFOLD
RECOMMENDED
SOUND BAFFLE
HANGER BRACKET
BY MODERNFOLD
FINISHED
CEILING
.75"
(19 mm)
#17 STEEL TRACK AND
ALUMINUM GUIDE RAIL
PREPAINTED WHITE
STEEL, 4-WHEEL
BALLBEARING TROLLEYS
VINYL TOP SEAL
Model Detail from Website
4.25"
(108 mm)
TRACK
AS-03
8Please contact your local Modernfold distributor for further assistance, or visit our website at .
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
SUSPENSION SYSTEM OPTIONS
#14 Track System Bracket Mount
7.50" (191 mm)
BRACKET
5" (127 mm) GAGE
1
3
"
(
3
3
0
m
m
)
M
I
N
I
M
U
M
.50" (13 mm) DIA
× 9" (229 mm) LONG
HANGER RODS
BY MODERNFOLD
HANGER BRACKET
BY MODERNFOLD
.75"
(19 mm)
FINISHED
CEILING
CONTINUOUS STEEL
TRACK
STEEL BALLBEARING
TROLLEYS
OFF WHITE
CONTINUOUS STEEL
SOFFIT TRIM PAN
BY MODERNFOLD
VINYL TOP SEAL
10.25" (260 mm)
SOFFIT
Model Detail from Website
AS-10
Please contact your local Modernfold distributor for further assistance, or visit our website at .9
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
SUSPENSION SYSTEM OPTIONS
#30 Track System Standard Spacing
3.50"
(89 mm)
GAGE
2.50"
(64 mm)
GAGE
STRUCTURAL
SUPPORT NOT
BY MODERNFOLD
.38" (10 mm) DIA
× 9" (229 mm)
LONG HANGER
RODS BY
MODERNFOLD
HANGER BRACKET
BY MODERNFOLD
#30 Track System Optional Wider Spacing
5.50"
(140 mm)
GAGE
4.50"
(114 mm)
GAGE
STRUCTURAL
SUPPORT NOT
BY MODERNFOLD
1
3
"
(
3
3
0
m
m
)
M
I
N
I
M
U
M
1
3
"
(
3
3
0
m
m
)
M
I
N
I
M
U
M
.38" (10 mm) DIA
× 9" (229 mm)
LONG HANGER
RODS BY
MODERNFOLD
HANGER
BRACKET BY
MODERNFOLD
.75"
(19 mm)
CLG
LINE
STEEL
BALLBEARING
TROLLEYS
VINYL TOP SEAL
CLG
LINE
.75"
(19 mm)
STEEL
BALLBEARING
TROLLEYS
VINYL
TOP SEAL
F
A
B
R
I
C
A
T
I
O
N
H
E
I
G
H
T
F
A
B
R
I
C
A
T
I
O
N
H
E
I
G
H
T
5.38"
(137 mm)
TRACK
5.38"
(137 mm)
TRACK
Model Detail from Website
Model Detail from Website
AS-119
AS-120
10Please contact your local Modernfold distributor for further assistance, or visit our website at .
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
PANEL, WORK SURFACE, AND PASS DOOR OPTIONS
SELF-LUMINOUS EXIT SIGNS
(SURFACE OR RECESSED MOUNTED)
NO VERTICAL TRIM
ON PANEL (TYPICAL)
6
'
-
8
"
(
2
0
3
3
m
m
)
O
R
7
'
-
0
"
(
2
1
3
4
m
m
)
"H" TYPE PASS
DOOR
SELF-LUMINOUS
EXIT SIGN (OPTIONAL
LOCATION)
CHALKBOARD, MARKERBOARD,
OR TACKBOARD (NO VERTICAL
TRIM REQUIRED)
RECESSED HAND PULL WITH
FRICTION LATCH (ADA COMPLIANT)
RECESSED ERASER
HOLDER
FLOOR SEAL OPTIONS
2-inch Automatic Seal2-inch Manual Seal
2"
(51 mm)
AUTOMATIC DROP SEAL
PROVIDES 2" (51 mm)
OPERATING CLEARANCE
+ .50" (13 mm) / –1.50" (38 mm)
FLOOR
2"
(51 mm)
MANUAL DROP SEAL
ACCOMMODATES
+ .50" (13 mm) TO
–1.50" (38 mm)
DEFLECTION AND/OR
FLOOR VALANCE
FLOOR
Model Detail from WebsiteModel Detail from Website
AS-12C
Please contact your local Modernfold distributor for further assistance, or visit our website at .
AS-11
11
V
A
R
I
A
B
L
E
4
'
-
0
"
(
1
2
2
0
m
m
)
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
POCKET ENCLOSURE AND STACKING OPTIONS
Expandable Jamb Closure -
Even Panel Quantity
Expandable Jamb Closure -
Odd Panel Quantity
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
7
"
(
1
7
8
m
m
)
M
I
N
.
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
4
"
(
1
0
2
m
m
)
M
I
N
.
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
4
"
(
1
0
2
m
m
)
M
I
N
.
SIDE R
SIDE L
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
7
"
(
1
7
8
m
m
)
M
I
N
.
SIDE R
SIDE L
OPTIONAL
STACK
DEPTH
NO. OF PANELS
× 3.75" (95 mm) + 2" (51 mm)
OPTIONAL
STACK
DEPTH
NO. OF PANELS
× 3.75" (95 mm) + 2" (51 mm)
Remote Expandable Jamb Closure
STACK TH
PLUS
6" (152 mm)
MIN.
TYPE II
DOOR
Angle Jamb Closure -
Odd Panel Quantity
1
/
2
P
A
N
E
L
W
I
D
T
H
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
P
L
U
S
7
"
(
1
7
8
m
m
)
1
0
"
(
2
5
4
m
m
)
M
I
N
.
M
I
N
.
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
7
"
(
1
7
8
m
m
)
M
I
N
.
SIDE R
SIDE L
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
4
"
(
1
0
2
m
m
)
M
I
N
.
SIDE R
SIDE L
STACK
DEPTH
NO. OF PANELS
× 3.75" (95 mm) + 2" (51 mm)
OPTIONAL
STACK
DEPTH
NO. OF PANELS
× 3.75" (95 mm) + 5" (127 mm)
12Please contact your local Modernfold distributor for further assistance, or visit our website at .
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
POCKET ENCLOSURE AND STACKING OPTIONS
Angle Jamb Closure -
Even Panel Quantity
Pass Door Closure
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
7
"
(
1
7
8
m
m
)
M
I
N
.
T
R
A
I
L
P
A
N
E
L
S
I
Z
E
P
L
U
S
4
"
(
1
0
2
m
m
)
M
I
N
.
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
4
"
(
1
0
2
m
m
)
M
I
N
.
SIDE R
SIDE L
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
7
"
(
1
7
8
m
m
)
M
I
N
.
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
4
"
(
1
0
2
m
m
)
M
I
N
.
SIDE R
SIDE L
OPTIONAL
STACK
DEPTH
NO. OF PANELS
× 3.75" (95 mm) + 5" (127 mm)
STACK
DEPTH
NO. OF PANELS
× 3.75" (95 mm) + 4" (102 mm)
Bi-fold Hinged Panel Closure
Single Hinged Panel Closure
1
/
2
P
A
N
E
L
W
I
D
T
H
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
P
L
U
S
4
"
(
1
0
2
m
m
)
7
"
(
1
7
8
m
m
)
M
I
N
.
M
I
N
.
1
/
2
P
A
N
E
L
W
I
D
T
H
1
/
2
P
A
N
E
L
W
I
D
T
H
P
L
U
S
P
L
U
S
4
"
(
1
0
2
m
m
)
7
"
(
1
7
8
m
m
)
M
I
N
.
M
I
N
.
SIDE R
SIDE L
SIDE R
SIDE L
OPTIONAL
STACK
DEPTH
NO. OF PANELS
× 3.75" (95 mm) + 4" (102 mm)
STACK
DEPTH
OPTIONAL
NO. OF PANELS
× 3.75" (95 mm) + 4" (102 mm)
Please contact your local Modernfold distributor for further assistance, or visit our website at .13
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
PANEL CROSS SECTIONS
Hinged Jamb
Expandable Panel w/ Jamb
CAULKING BETWEEN
JAMB AND WALL
CAULKING
BETWEEN
JAMB AND
WALL
0" TO 5.75"
(146 mm)
TRAVEL
EXPANDABLE PANEL
NOSE - FINISH
SAME AS PANELS
Model Detail from WebsiteModel Detail from Website
AS-31RAS-34
Expandable Panel w/ Bulb Seal
Angle Jamb
0" TO 5.75"
(146 mm)
TRAVEL
EXPANDABLE PANEL
NOSE
END CAP
VINYL SWEEP
VINYL BULB SEAL
CAULKING
BETWEEN
JAMB AND WALL
STEEL ANGLE WRAPPED
WITH FINISH MATERIAL
Model Detail from Website
Model Detail from Website
AS-36
AS-39R
14Please contact your local Modernfold distributor for further assistance, or visit our website at .
®
932
Technical Data
10 22 26
Operable Partitions
ACOUSTI-SEAL
®
900 SERIES TECHNICAL DATA
PANEL CROSS SECTIONS
Hinged Panel Meeting w/ Bulb Seal
Hinged Panel Meeting
w/ Pass Door Astragal
1"
(25 mm)
1.50"
(38 mm)
REF.
STOPS
Model Detail from Website
Model Detail from Website
ALUMINUM ASTRAGAL
COVERED TO MATCH
PANEL FINISH (OPTIONAL)
AS-69R
Nominal Fixed Jamb
CAULKING BETWEEN
JAMB AND WALL
AS-43L
Bulb Seal and Intersection
VINYL BULB
SEAL
Model Detail from Website
3
.
0
0
"
(
7
6
m
m
)
R
E
F
VINYL SEAL AND
STEEL ASTRAGAL
Model Detail from Website
AS-21
Variable Fixed Jamb
CAULKING
BETWEEN JAMB
AND WALL
AS-49
Model Detail from Website
AS-22
Please contact your local Modernfold distributor for further assistance, or visit our website at .15
®
932
Technical Data
10 22 26
Operable Partitions
Modernfold, Inc.
215 West New Road
Greenfield, IN 46140
Toll Free: 800.869.9685
email:*******************
A DORMA Group Company
Form No. 2502 8/08 - EREV 9/09
Manufacturer reserves the right to change design or specifications at any time without notice.