admin 管理员组文章数量: 1087139
2024年4月28日发(作者:css语言中背景图像的属性)
车 床 报 警 说 明
序号
2001
英文注释
The Emergency push button s/w is pressed. The X
or Zaxis multi-limit s/w is tripped out.
The x or z axis multi-limit switch is tripped out.
2002
2003
2004
2005
2007
2008
2009
2010
2012
2013
2014
2017
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
中文注释
急停按钮被按下或X,Z轴限位开关被压下
X,Z轴限位开关被压下
The 1st spindle is in the Emergency status(It comes
第一主轴在急停状态(主轴在报警状态此报警出现)
out when a 1st spindle alarm occurs)
The control circuit protectors are tipped out or fuse blown
空气开关跳脱或保险丝熔断
The hydraulic motor is overloaded
液压马达过载
The hydraulic pressure becomes below the set
油压压力在设定值以下
value..
Trouble of hydraulic pressure s/w
油压压力开关故障
The zero-speed detection or the speed detection of
主轴马达零速检测器或速度检测器无检测
spindel motor is not detected.
Fault of gear shift confirmation switch.
换挡开关出错
The 2nd spindle Emergency status.(It comes out
第2主轴在急停状态(2主轴在报警状态此报警出现)
when a 2nd spindle alarm occurs)
Machine is in Not Ready status.
机床准备不足状态
The X-axis torque limiter s/w is tripped out.
X轴扭力开关被绊住
Trouble of x-axis torque limiter switch
X轴扭力开关出错
The Z-axis torque limiter s/w is tripped out.
Z轴扭力开关被绊住
Trouble of z-axis torque limiter switch
Z轴扭力开关出错
The B-axis torque limiter s/w is tripped out.
B轴扭力开关被绊住
Trouble of B-axis torque limiter switch
B轴扭力开关出错
The hydraulic oil of drain oil reservoir is overflowed.
液压蓄油池过溢报警
Trouble of float switch in the oil reservoir
液压蓄油池过溢出错
Keep relay setting to define the machine model is
关于机床种类的K参数没有设定
not selected
The AC motor is overloaded.(coolant or lubrication
马达过载(冷却马达或润滑油马达)
pump motor)
The Torque limit SKIP command is used incorrectly.
使用扭力限制跳过命令出错
The spindle orientation command (m19) is not accepted.
主轴定位命令没有执行
The tool change command is not accepted.
换刀命令没有执行
Incorrect tool commanded.
错误的刀浩命令
Keep relay setting to define the tool post model is
控制刀塔型号的K参数没有设定
not selected
The gear shift command(M41/M42/M43/M44)is not
换挡命令没有执行
accepted
The spindle speed arrival signal is not detected.
主轴速度抵达信号出错
Spindle rotation command(M03/M04)is not accepted.
主轴旋转命令没有执行
The splash guard door is opened
防溅门开
Trouble of door interlock limit switch
门互锁限制开关故障]
Machine Lock command(M17/M18)is commanded
在不正确的模式执行机床锁定指令
in the improper mode.
The reference point return is not completed.
原点复归没有完成
In auto mode ,FEED HOLD status
自动模式下进给保持
Air pressure becomes below the set value
气压在设定值以下
Trouble of Air pressure limit switch
气压限位开关故障
Proximity switch to detect the chucking
卡盘夹紧近接确认开关位置错误
confirmation is at a wrong position.
Trouble of chucking confirmation limit switch
卡盘夹紧近接确认开关故障
序号英文注释
2035
The axis change command is not accepted
Chuck clamp/unclump command (M68/M69) is not
2036
accepted.
Proximity switch to detect the tailstock quill
confirmation is at a wrong pos
2037
Tailstock quill operation command (M78/M79)is not
accetted
Trouble of tailstock quill confirmation switch
The Programmable Tailstock command(M46/M47)
2038
IS NOT accepted
The part catcher command(M10/M11) is not
2039
accepted
2040
The bar-feeder command(M50/M51) is not accepted
2041
The alarm occurs at the Bar-feeder side.
The Auto door operation command (M52/M53)is
2042
not accepted
The steady rest operation command
2043
(M38/M39/M58/M59) is not accepted
The part catcher is advanced,even though M10 is
2044
not commanded
The Quick tool setter operation
2045
command(M80/M81)is not accepted.
2046
The chuck is opened,even though M69 is not commanded
2047
The encoder signal error for turret positioning is detected
2048
The reset (RST)command is used while program is running
The C-axis operation command(M88/M89/M90)is
2049
not accepted
2050
Lack of lubrication oil.
2051
Lack of coolant oil.
2052
Trouble of proximity switch to detect chucking confirmation
2053
Revolving tool is not engaged
Synchronous command(M203/M204)is used in the
2055
improper condition
The M-codes for main and sub-spindle
2056
rotation,without M206 between those commands,is
2057
The tool life is reached at its expectancy
2058
The parts counting is reached at the limit value set
The cycle start command is invalid because the
2060
chuck is not in clamp
Trouble of the limit switch to detect the
2062
programmable tailstock operation
Trouble of proximity switch to detect the quick tool
2063
setter operation
2090
The feedrate value (f0%)srtter error
The reference point return is commaned,thougH
2093
each axis is alreAdy at its reference position
2096
The feedrate override is 0%
2097
The machine lock status
2098
The M00/M01 command status .
2099
The M02/M30 command status .
中文注释
轴转换命令没有执行
卡盘夹紧/放松命令没有执行
尾座套筒位置检测开关位置错误
尾座套筒伸出/收回命令没有执行
尾座套筒位置检测开关故障
可程式尾座命令没有执行
工件收集器指令没有执行
棒料送料器指令没有执行
棒料送料器出现报警
自动门指令没有执行
中心架指令没有执行
即使M10没有指令,零件收集器也伸出
对刀仪命令没有执行
即使M69指令没有执行,卡盘还是打开
刀塔旋转指令编码器检测错误K5.4刀塔松开
程序运转中使用复位指令
C-轴松紧指令没有执行
缺润滑油
缺冷却液
卡盘夹紧近接确认开关故障
旋转刀具使用中
同步运转指令使用不恰当
主轴和副主轴的M码使用问题
刀具寿命超出设定范围
工件记数超出设定范围
卡盘没有夹紧就执行循环启动
可编程尾座限位开关故障
对刀仪运转检测开关故障
被率设定为0错误
执行原点复归指令,可是各轴已经在原点位置
G01被率开关设定为0
机床锁定状态
M00/M01状态
M02/M30 状态