admin 管理员组文章数量: 1086019
2024年3月26日发(作者:删除文件恢复大师软件破解版)
欧陆590驱动器
Parameter Upread / Download 参数上传,下载
If you wish to copy the parameters then the cable detailed below will be required.
通讯电缆接线如下
P3 (FCC-68 4 way)
驱动器侧接口P3
1
2
3
4
Signal
信号
0V
+24V
TX
Rx
Female 9 Pin D Type
电脑测接口:9针母头
5
Not connected不要连接
2
3
Do not connect P3 pin 2 ! It could damage your PC.
警告:(驱动器侧接口)P3的2号针不要连接到电脑COM口(9针母头),它会损坏电脑
注意:P3侧是用用于电话听筒上的水晶接头,如下图所示
接线顺序如上图示,接线端在上,从左到右依次是1-4号
Procedures步骤如下
1. Hyperlink can be accessed by opening 按照下面打开超级终端
STARTPROGRAMSACCESSORIESCOMMUNICATIONSHYPERLINK.
开始程序附件通讯超级终端,见下附图
2. Open , this will ask you to name your specific setup
eg. EUROTHERM 590. 打开超级终端后,并命名。
3. Change 'Connect to' so it reads 'Direct to com 1'. 选择电脑所连接的端口。
4. In the 'Port settings' menu change 'Bits per second' to '9600' and 'Flow control' to
'xon-xoff'. 端口设置,波特率改9600,流量改为Xon/Xoff
5. At the top of the window highlight 'Transfer' then click on 'Capture text' this will
enable you to upload MMI and UDP files from the drive. 在菜单‘Transfer传送’下面
的‘CaptureText捕捉’,选择文件格式MMI或UDP,MMI是可读参数,只能上传到电脑,
不能下载到驱动器,带星号的参数表示可以手动修改的;UDP是机器码参数,可以上传到电脑
也可以下载到驱动器。
6. Enter where you would like the file to be saved and what you are going to name it.
给要保存的文件命名
7. On the drive setup 'DUMP MMI>P3' (or upd) via SERIAL LINKSSYSTEM PORT(P3).
在驱动器上选择端口,在SerialLinksSYSTEM PORT P3
8. It is important to note that the unit receiving information should be initiated first
then after a few seconds the unit sending information. 接受方需要进行初始化设置,然
后才可以发送
ading from the Drive, initiate the PC first. Upreading to the Drive,initiate
the Drive first. 比如从驱动器上传参数,先初始化电脑,下载参
数到驱动器,先初始化驱动器。
downloading has finished highlight 'Capture text' and click on 'Stop' and you
have finished. 上传完成后,选择‘Capture text捕捉文本’
When uploading to a drive you should highlight 'Tranfer' and click on 'Send text file',
then set 'UDP XFER←P3'(remember to initiate the drive first). 下载参数到驱动器,选择
‘Transfer传送’,点‘Send text file’,在驱动器上选择‘UDP XFER←P3’
If the transfer was successful the drive displays the message''E' to continue', press 'E'
and the drive should then do a self test. 如果传送成功,会显示‘E’,按‘E’后驱动器
会自检。the parameter changes must be saved to EPROM via MENU ->SAVE Param
then press the ▲key to save the changes. 修改参数后记得保存,就要到‘Meun菜单’,
选择SaveParam保存参数,然后按上箭头。
注意:上图是驱动器的操作面板,其中E标示退出,M标示进入菜单,向上箭头表示上下移动
菜单项或确认操作,向下箭头表示移动菜单项。DUMP MMI→P3表示从驱动器上传参数到电
脑,UDP文件大小约为26KB,MMI文件约为4KB,格式为文本文件TXT。
版权声明:本文标题:欧陆590驱动器参数上传与下载 内容由网友自发贡献,该文观点仅代表作者本人, 转载请联系作者并注明出处:http://roclinux.cn/b/1711406083a592463.html, 本站仅提供信息存储空间服务,不拥有所有权,不承担相关法律责任。如发现本站有涉嫌抄袭侵权/违法违规的内容,一经查实,本站将立刻删除。
发表评论